Oscilloscopes WaveMaster 8 Zi

FournisseursLecroy

LeCroy has broken bandwidth barriers by combining proven SiGe components with 5th generation Digital Bandwidth Interleave technology to achieve unprecedented real-time oscilloscope performance: 30GHz, 80GS/s, and 512Mpts/Ch Starting price from $66000

Preloader

 

WaveMaster 804Zi (4 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch (80 GS/s on 2 Ch) Max Sample Rate)

Analog (ProLink Input) Bandwidth @ 50 ? (-3 dB) 4 GHz

(?10 mV/div)

Input Channels 4 (Any combination of ProLink and ProBus inputs)

Single-Shot Sample Rate/Ch 40 GS/s on 4 Ch (80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)

Standard Memory (4 Ch / 2 Ch) (Number of Segments) 10 M / 10 M 

(optional WM8Zi-2X80GS External Interleaving Device permits 80 GS/s on 2ch with twice the memory)

(5000)

WaveMaster 806Zi (6 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch (80 GS/s on 2 Ch) Max Sample Rate)

Analog (ProLink Input) Bandwidth @ 50 ? (-3 dB) 6 GHz

(?10 mV/div)

Input Channels 4 (Any combination of ProLink and ProBus inputs)

Single-Shot Sample Rate/Ch 40 GS/s on 4 Ch (80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)

Standard Memory (4 Ch / 2 Ch) (Number of Segments) 10 M / 10 M

(optional WM8Zi-2X80GS External Interleaving Device permits 80 GS/s on 2ch with twice the memory)

(5000)

WaveMaster 808Zi (8 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch (80 GS/s on 2 Ch) Max Sample Rate)

Analog (ProLink Input) Bandwidth @ 50 ? (-3 dB) 8 GHz

(?10 mV/div)

Input Channels 4 (Any combination of ProLink and ProBus inputs)

Single-Shot Sample Rate/Ch 40 GS/s on 4 Ch (80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)

Standard Memory (4 Ch / 2 Ch) (Number of Segments) 10 M / 10 M 

(optional WM8Zi-2X80GS External Interleaving Device permits 80 GS/s on 2ch with twice the memory)

(5000)

WaveMaster 813Zi (13 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch (80 GS/s on 2 Ch) Max Sample Rate)

Analog (ProLink Input) Bandwidth @ 50 ? (-3 dB) 13 GHz

(?10 mV/div)

Input Channels 4 (Any combination of ProLink and ProBus inputs)

Single-Shot Sample Rate/Ch 40 GS/s on 4 Ch (80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)

Standard Memory (4 Ch / 2 Ch) (Number of Segments) 10 M / 10 M 

(optional WM8Zi-2X80GS External Interleaving Device permits 80 GS/s on 2ch with twice the memory)

(5000)

WaveMaster 816Zi (16 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch (80 GS/s on 2 Ch) Max Sample Rate)

Analog (ProLink Input) Bandwidth @ 50 ? (-3 dB) 16 GHz

(?10 mV/div)

Input Channels 4 (Any combination of ProLink and ProBus inputs)

Single-Shot Sample Rate/Ch 40 GS/s on 4 Ch (80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)

Standard Memory (4 Ch / 2 Ch) (Number of Segments) 10 M / 10 M 

(optional WM8Zi-2X80GS External Interleaving Device permits 80 GS/s on 2ch with twice the memory)

(5000)

WaveMaster 820Zi (16 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch (80 GS/s on 2 Ch) Max Sample Rate)

Analog (ProLink Input) Bandwidth @ 50 ? (-3 dB) 16 GHz

(?10 mV/div)

Input Channels 4 (Any combination of 16 GHz ProLink inputs or 3.5 GHz ProBus inputs), 

3 (1 @ full BW, 2 with ProLink or ProBus inputs), or 

2 (@ full BW)

Single-Shot Sample Rate/Ch 40 GS/s on 4 Ch (80 GS/s on 2 Ch when operated in ?20 GHz Mode)

Standard Memory (4 Ch / 2 Ch) (Number of Segments) 10 M / 10 M

(20 Mpts in 2 Ch mode when operated in ?20 GHz Mode)

(5000)

WaveMaster 825Zi (16 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch (80 GS/s on 2 Ch) Max Sample Rate)

Analog (ProLink Input) Bandwidth @ 50 ? (-3 dB) 16 GHz

(?10 mV/div)

Input Channels 4 (Any combination of 16 GHz ProLink inputs or 3.5 GHz ProBus inputs), 

3 (1 @ full BW, 2 with ProLink or ProBus inputs), or 

2 (@ full BW)

Single-Shot Sample Rate/Ch 40 GS/s on 4 Ch (80 GS/s on 2 Ch when operated in ?20 GHz Mode)

Standard Memory (4 Ch / 2 Ch) (Number of Segments) 10 M / 10 M

(20 Mpts in 2 Ch mode when operated in ?20 GHz Mode)

(5000)

WaveMaster 830Zi (16 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch (80 GS/s on 2 Ch) Max Sample Rate)

Analog (ProLink Input) Bandwidth @ 50 ? (-3 dB) 16 GHz

(?10 mV/div)

Input Channels 4 (Any combination of 16 GHz ProLink inputs or 3.5 GHz ProBus inputs), 

3 (1 @ full BW, 2 with ProLink or ProBus inputs), or

2 (@ full BW)

Single-Shot Sample Rate/Ch 40 GS/s on 4 Ch (80 GS/s on 2 Ch when operated in ?20 GHz Mode)

Standard Memory (4 Ch / 2 Ch) (Number of Segments) 10 M / 10 M

(20 Mpts in 2 Ch mode when operated in ?20 GHz Mode)

(5000)

 


PRODUITS EN PROMOTIONS

Promo!
PKF2 FPS-SitosecFPS_200ml_h600-RGB6

Nettoyants de précision Nettoyant sec à séchage ...

Promo!
PKF2 Ordinet_100ml_h600-RGB5

Chasse l'humidité et protège. - Élimine l'humidité des ...

Promo!
PKF2 Ordinet_100ml_h600-RGB

Nettoyant sec des têtes et disques magnétiques - ...

Promo!
PKF2 FPS-SitosecFPS_200ml_h600-RGB

SITOSEC FPS Nettoyant sec à séchage rapide. - Nettoyant ...

NOUVEAUX PRODUITS

New!
78

DDSE-2B: Station de soudage/dessoudage

New!
12)

DMSE-2A: Station de soudage/dessoudage; digital; DES; 300W; ...

New!
alr3206d__084934300_0913_22062016

Alimentation programmable 2x 0 -32V ; 0 - 6A ; 390W CODE ...

New!
ca1954

Ergonomique, simple à utiliser, la caméra thermique C.A ...

New!
imagen_01 (2)9

Ref. CA-2E 230V The CA is a soldering station for ...

New!
99_

DIR-2D Station de soudage; digital; DES; 40W; 90÷450°C; ...

New!
imagen_01 (6)

Ref. DDE-2B 230 V This control unit manages up to 2 ...

New!
ca6526_f_2550-1000v_2

Contrôleur d’isolement et de Continuité, 50V-100V-250V-1 kV ...